0 ratings
Current Transformer 63A0.1A 630turns for DKM-430, Closed Loop Type
Item #: 88425085

Current Transformer 63A0.1A 630turns for DKM-430, Closed Loop Type

Item #: 88425085

RWF 66515

Price Details

Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )

*All items will import from US

0 ratings Write a review
In stock
us Imported from USA store

QTY:

Order now and get it around Monday, July 27
Our Top Logistics Partners
  • fedex
  • dhl
U-Care Warranty:
None
Select a Plan
fast shipping

Fast
Shipping

free return

Free
Return*

secure packaging

Secure Packaging

100% original products

100% Original Products

pci-dss

PCI DSS Compliance

iso certified

ISO 27001 Certified


paypal payment
visa payment
mastercard payment
Note: Step Down Voltage Transformer required for using electronics products of US store (110-120). Recommended power converters Buy Now.

What Stands Out

High Accuracy
The closed loop design provides exceptional measurement precision, ensuring reliable current sensing for electrical applications, minimizing errors compared to traditional open loop transformers.
Compact Design
With a maximum rating of 63A, the compact structure enables easy installation in tight spaces, making it ideal for diverse applications while maintaining robustness and efficiency.
Versatile Compatibility
Designed for use with DKM-430, this transformer easily integrates into existing systems, maximizing usability across various setups without compromising performance or functionality.

Product Details

Shop Current Transformer 63A0.1A 630turns for DKM-430, Closed Loop Type online at a best price in Rwanda. B0CR3XJZWH
Item Weight1.5 lbs (680 grams)

Who Should Buy?

Suitable For
  • Electrical Engineers

    Perfect for electrical engineers needing accurate current measurement for circuit analysis and monitoring in various applications.

  • Energy Managers

    Ideal for energy managers aiming to efficiently monitor and reduce energy consumption in industrial setups.

  • Utility Companies

    Beneficial for utility companies for stable and precise current readings in grid management and customer metering.

Not Suitable For
  • DIY Enthusiasts

    Not ideal for DIY enthusiasts lacking the necessary experience to install complex electrical components safely and correctly.

  • Small Scale Applications

    Unsuitable for small scale applications where lower precision and lower current ratings are sufficient, increasing system costs unnecessarily.

  • Casual Users

    Not recommended for casual users or households needing basic current measurement without advanced features or higher accuracy.

Product Description

Current Transformer 63A0.1A 630turns for DKM-430, Closed Loop Type

Have any Query? Chat with us

Customer Questions & Answers

  • Question: What is a Current Transformer and how does it work?

    Answer: A Current Transformer (CT) is a device used to measure alternating current (AC) by producing a secondary current proportional to the primary current. It operates on the principle of electromagnetic induction. By capturing the magnetic field created by high voltage AC, the CT provides a scaled-down, safer current measurement suitable for connecting to measurement instruments. This makes it essential in power systems for monitoring and protecting electrical circuits.
  • Question: What are the specifications of the Current Transformer 63A0.1A 630turns?

    Answer: The Current Transformer 63A0.1A 630turns features a primary current capacity of 63A and a transformation ratio of 630:0.1A. This means it can safely monitor high current levels while providing reduced output for measurement purposes. Additionally, its closed-loop type design enhances accuracy and reliability, making it ideal for precise current measurements in industrial applications.
  • Question: What applications are suited for the Current Transformer 63A0.1A?

    Answer: This Current Transformer is ideal for use in power monitoring, energy management systems, and protection relays in various industrial settings. It's commonly deployed in substations, generator sets, and renewable energy systems to ensure accurate current measurement. The closed-loop design makes it particularly effective for applications requiring high accuracy and reduced measurement errors.
  • Question: Can the Current Transformer be used for both AC and DC measurements?

    Answer: No, the Current Transformer 63A0.1A is specifically designed for alternating current (AC) measurements. Its operation is based on the principles of electromagnetic induction, which only apply to AC. Using it for direct current (DC) applications could result in incorrect readings and potential damage to the device.
  • Question: How does the construction of a closed-loop Current Transformer differ from an open-loop model?

    Answer: Closed-loop Current Transformers have a design that includes a feedback mechanism, resulting in higher accuracy and stability in current measurement compared to open-loop models. This structure reduces measurement errors and external influences, making closed-loop CTs ideal for critical applications in industrial and commercial environments where precision is paramount.
  • Question: What safety features should I consider when using a Current Transformer?

    Answer: When using a Current Transformer, it is important to ensure proper insulation and protection against overcurrent or short circuits. Additionally, installing the CT within a defined operating range and using specified fuses or overcurrent protection devices can enhance safety. Considerations for proper grounding and isolation from high-voltage circuits also help to mitigate risks.
  • Question: How do I connect the Current Transformer to my measurement system?

    Answer: To connect the Current Transformer 63A0.1A, ensure you understand the wiring instructions. Typically, the primary conductor passes through the CT eye, while the secondary leads connect to the measurement device (like an ammeter or protective relay). Ensure the system is powered down before making connections, and verify all connections are secure to avoid measurement errors.
  • Question: What is the role of turns ratio in a Current Transformer?

    Answer: The turns ratio in a Current Transformer determines how the primary current is scaled down to the secondary current. For the 63A0.1A model, a 630:0.1 ratio means for every 630 turns on the primary side, there is 0.1A on the secondary side. This conversion allows measuring large currents safely with less complex equipment and is crucial for calibration in monitoring systems.
  • Question: Is calibration required for the Current Transformer?

    Answer: Calibration is an essential aspect of using a Current Transformer to ensure accuracy in measurements. Although the 63A0.1A has defined specs, periodic calibration against reliable reference devices is necessary to account for variations in manufacturing and environmental conditions. This process guarantees that the readings remain valid and reliable over time, particularly in critical applications.
  • Question: Where can I buy the Current Transformer 63A0.1A 630turns for DKM-430 in Rwanda?

    Answer: You can purchase the Current Transformer 63A0.1A 630turns for DKM-430 from Ubuy in Rwanda. Ubuy offers a wide selection of electrical components, ensuring that you can find specific products like this Current Transformer easily and conveniently.

DATAKOM Power Transformers Editorial Review

No editorial reviews found

Customer Reviews & Ratings

5.0
1 customers ratings
  • 5 Star
    100%
  • 4 Star
    0%
  • 3 Star
    0%
  • 2 Star
    0%
  • 1 Star
    0%

Review this product

Share your thoughts with other customers

Pros

  • High accuracy of measurement
  • Durable closed loop design
  • Compact and lightweight
  • Superior sensitivity levels
  • Easy installation process

Cons

  • Limited to specific applications

Product Price History

Important information

  • Limitations : For products shipped internationally, please note that any manufacturer warranty may not be valid; manufacturer service options may not be available; product manuals, instructions, and safety warnings may not be in destination country languages; the products (and accompanying materials) may not be designed in accordance with destination country standards, specifications, and labeling requirements; and the products may not conform to destination country voltage and other electrical standards (requiring use of an adapter or converter if appropriate). The recipient is responsible for assuring that the product can be lawfully imported to the destination country. When ordering from Ubuy or its affiliates, the recipient is the importer of record and must comply with all laws and regulations of the destination country.
  • Not all the products listed on Ubuy are for sale, as Ubuy is a global search engine. Products are subject to export/trade regulations.